Atlanta, GA

A load-bearing precast concrete beam on the fifth floor of an Atlanta condominium parking structure was found with a failed bearing and supporting corbel. As a result of these failures, the beam experienced some rotation, and one end of the beam displaced downward approximately one inch. Innovative Engineering Inc was retained by Atlantic Residential to perform an emergency site investigation to assess the condition of the damaged beam bearing and corbel. The bearing of the beam was found to have a deteriorated bearing pad and cracked and spalled concrete corbel. The corbel was observed to have cracks and large spalls across the face.

Following completion of the preliminary site investigation, developed and supervised the installation of shoring to remove load from the damaged corbel and beam bearing and transfer the loads from the fifth floor down to the ground. After the installation of shoring, construction documents were created detailing repair procedures for the damaged corbel and bearing. Innovative Engineering also supervised the progress of the repairs during construction.

Innovative Engineering's fast response and extensive experience with parking structure restorations ensured that the shoring and repair procedures were developed and implemented in an accelerated timeline.

 

Our Clients Include:

Air Tran
Anheuser-Busch
Caterpillar
CDC
Chevron
Chipotle
Clorox
Coca-Cola
Delta Airlines
Department of Defense
Emory
FBI
Fiat Industrial
General Motors
Georgia Tech
Hardees
KFC
Lilly
Marriot
Navy
Panda Express
Travelcenters of America
University of Georgia
United States Marine Corps
usace
USAF
USDA
USPS
Department of Verterans Affairs
GSA
GA Tech
AT&T
CBRE Group
Cushman & Wakefield
JLL
Colliers
Transwestern
Novelis
Jervis B Webb